Walkaway Capacity in Specimen/Tests Assays:

600-800 specimens System Liquid or Dry:

Liquid, ready to use Average Length of System Startup Time and Daily Maintenance:

3 minutes

Nova Biomedical 200 Prospect St. Waltham, MA 02454 Contact: Harlan Polishook Marketing Communications Manager Telephone: (781) 894-0800 Fax: (781) 894-5915 info@novabiomedical.com www.novabiomedical.com Primary Product: Stat Profile Critical Care Xpress Type of Analyzer: Blood gas/electrolyte/chemistry Methodologies Used: Ion selective electrode/ optical, reflectance Tests Available in the U.S.: pH, PCO2, PO2, hematocrit, hemoglobin, sodium, potassium, chloride, ionized calcium, ionized magnesium, glucose, BUN, creatinine, lactate, bilirubin, deoxyhemoglobin, oxyhemoglobin, methemoglobin, carboxyhemoglobin Throughput: 21-26 samples/hour Time to First Result: 65 seconds (normal throughput); 140 seconds (alternate throughput) Sample Size: 60-210 mL Frequency of Calibration: Automatic Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? Comprehensive 20-test critical care profile, including ionized magnesium, BUN, creatinine, and bilirubin; integrated co-oximetry; color touch screen, open software architecture, onboard data management; automate, onboard quality control; sealed waste system; auto-monitoring of

QC and reagent packs; tankless gas calibration; automated maintenance Operational Type: Individual sample Sample Handling System: Dock for syringe or capillary sample Number of Reagent Containers Onboard/Tests/Container: Two—one reagent container for ABG/ chemistry and one for co-oximeter/2,600 to 6,500 tests per container depending on laboratory use pattern Reagents Refrigerated Onboard: No System Liquid or Dry: Liquid/ISE Average Length of System Startup Time and Daily Maintenance: <5 minutes

Olympus America Inc. 3500 Corporate Parkway Center Valley, PA 18034 Contact: Frank Bartholf Senior Product Manager Telephone: (800) 223-0125 Fax: (484) 896-7131 olympusdsg@olympus.com www.olympusamerica.com Primary Product: Olympus AU chemistry-immuno systems Type of Analyzer: Chemistry-immuno analyzers Methodologies Used: Endpoint, potentiometric, kinetic rate and fixed rate Tests Available in the U.S.: 125-test menu including general, stat and urine chemistries, serum proteins, therapeutic and drug of abuse assays Throughput: 400-6,600 tests per hour, model dependent Time to First Result: 2–9 minutes depending on analyzer and mode of operation such as stat or routine Sample Size: 1-20 mL, test dependent Frequency of Calibration: 30 days (median) Integrated Data Management: Yes Open Reagent System: Yes Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes

Other Utility Requirements: Deionized water, drain What differentiates your product from other products on the market? Olympus Standardization meets laboratories’ workflow needs with four chemistry-immuno analyzers standardized for greater efficiency for the hospital core lab, satellite lab, outpatient lab, single and multiple locations, with throughput speeds from 400–6,600 tests per hour. Olympus 125 Test Menu streamlines workflow by consolidating testing with fewer workstations, faster TAT and greater capacity. Lab automation reduces sample handling labor and errors while improving turnaround time. Service and support provides comprehensive customer-tailored solutions to increase productivity and ensure maximum system uptime with reliable results. Operational Type: Fully selective discrete, random access Separation Methodologies: Homogeneous Sample Handling System: Rack and 22-position stat carousel Number of Reagent Containers Onboard/Tests/Container: 76-96 onboard reagent cartridges (model dependent); 50-4,000 tests per cartridge (test dependent) Reagents Refrigerated Onboard?: Yes Walkaway Capacity in Specimen/Tests Assays: 6,500 to 65,000 tests, model dependent System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: 5 minutes

Ortho-Clinical Diagnostics 1001 US Highway 202 Raritan, NJ 08869 Contact: Greg Winther Marketing Manager Telephone: (908) 218-8116 Fax: (908) 704-6837 gwinther@ocdus.jnj.com www.orthoclinical.com Primary Product: VITROS 5,1 FS Chemistry System Type of Analyzer: Chemistry Methodologies Used: Colorimetric, Immunorate, Potentiometric, Turbidimetric Tests Available in the U.S.: Acetaminophen Acid Phosphatase

s

Albumin Alcohol Alkaline Phosphatase ALT Ammonia Amylase AST BuBc Bilirubin BUN/Urea Calcium Carbamazepine Carbon Dioxide Chloride Cholesterol Cholinesterase CK CK-MB CRP Creatinine (Enzymatic) CSF Protein Digoxin GGT Glucose Iron Lactate LDH Lipase Lithium Magnesium Phenobarbital Phenytoin Phosphorus Potassium Salicylate Sodium Theophylline Total Bilirubin Total Protein Triglycerides TIBC Uric Acid Urine Protein Expanded Menu AAT AmphetaminesU Apo A1 Apo B ASO BarbituratesU BenzodiazepinesU C3 C4 Caffeine CannabinoidsU Cocaine MetabolitesU d%A1c dHDL (MicroSlide format) dLDL dTIBC Gentamicin Haptoglobin Homocysteine hsCRP IgA IgG IgM MethadoneU Microalbumin OpiatesU PhencyclidineU Prealbumin Rheumatoid Factor Tobramycin Transferrin Valproic Acid Vancomycin 10 user-defined channels (U-Urine) Throughput: Text mix dependent Time to First Result: 3 minutes Sample Size: 2-17 uL Frequency of Calibration: Up to 6 months calibration Integrated Data Management: Yes Open Reagent System: Yes Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? No water, drains, fixed probes or mixing assemblies required. Calibration stability up to lot change. Wide accessible menu with 125 reagent positions on board. Eliminates the additional cost, maintenance, carry-over and contamination risks associated with traditional water-based systems. Intelligent Parallel Processing integrating MicroSlideT and MicroTipT Technologies. Automated capping/ decapping of MicroTip reagents. User-defined assay capability. Operational Type: Continuous random access Separation Methodologies: Homogenous Sample Handling System: Universal sample tray