«laboratory analyzers buyers guide

»

offering continuous operation without interruption to workflow; minimized operator intervention using intuitive Windows 2000 Professional software; 2D bar code for reagent, calibration and control value import Operational Type: Continuous random access Sample Handling System: Primary tubes (capped and uncapped) and sample cups Number of Reagent Containers Onboard/Tests/Container: Up to 60 reagents onboard/ varies with assay Reagents Refrigerated Onboard: Yes, 44 reagents Walkaway Capacity in Specimen/Tests Assays: 120 continuous loading walkaway capacity/up to 30 tests per sample System Liquid or Dry: Liquid Average Length of System Startup and Daily Maintenance: <10 minutes

Integrated Data Management:

Yes Open Reagent System:

Yes Primary Tube Sampling:

Yes Positive Sample ID:

No Onboard Dilution:

Yes Other Utility Requirements:

Deionized water What differentiates your product from other products on the market?

5-parameter true random access clotting/chromogenic; standard in cap piercing; small footprint; complete automation; specialty assay capability; low operating expense Operational Type:

Continuous random access Sample Handling System:

Rack Number of Reagent Containers Onboard/Tests/Container:

11 containers/tests vary Reagents Refrigerated Onboard:

Dade Behring 1717 Deerfield Rd. Deerfield, IL 60015 Contact: Amy Boyett Senior Communications Specialist Telephone: (847) 267-5300 Fax: (847) 236-7101 amy_boyett@dadebehring.com www.dadebehring.com Primary Product: Sysmex® CA-530 Coagulation Analyzer Type of Analyzer: Coagulation Methodologies Used: Optical based system. Clotting and chromogenic methodologies used Tests Available in the U.S.: PT, APTT, Fibrinogen, TT, Factor Assays, Reptilase time, Protein C clot, AT III, Protein C chromo, heparin Throughput: 54 PT tests/hour, 43 PT/APTT tests/hour Time to First Result: 7 minutes Sample Size: 50 µL PT, 100 µL APTT Frequency of Calibration: Assay dependent. CLIA guidelines recommend calibration at least once every six months. More frequent calibration may be required if lab determines QC is outside the acceptable range or as dictated by local regulations.

Yes Walkaway Capacity in Specimen/Tests Assays:

10 specimens/assays vary System Liquid or Dry:

Liquid Average Length of System Startup Time and Daily Maintenance:

Daily maintenance < 5 minutes

Primary Product: Sysmex® CA-1500 Coagulation Analyzer Methodologies Used: Optical based system. Clotting, chromogenic and immunologic methodologies used Tests Available in the U.S.: PT, APTT, Fibrinogen, TT, Reptilase time, Factor Assays, drVVt screen and confirm, Factor V Leiden, Protein C clot, Protein S activity, AT III, Plasminogen, Factor VIII chromo, Alpha-2 Antiplasmin, Protein C chromo, Heparin, D-Dimer Throughput: 120 PT tests/hour, 80 PT/APTT tests/hour Time to First Result: 7 minutes Sample Size: 50 µL PT, 100 µL APTT Frequency of Calibration: Assay dependent. CLIA guidelines recommend calibration at least once every six months. More frequent calibration may be required

if laboratory determines QC is outside of the acceptable range or as dictated by local regulations. Integrated Data Management: Yes Open Reagent System: Yes Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes Other utility requirements: Deionized water required, container or direct plumbed option What differentiates your product from other products on the market? Simultaneous curve calibrating and patient testing; standard in cap piercing; ability to load multiple bottles or multiple lots of reagents Operational Type: Continuous random access Sample Handling System: Rack Number of Reagent Containers Onboard/Tests/Container: 39 containers/tests vary Reagents Refrigerated Onboard: Yes Walkaway Capacity in Specimen/Tests Assays: 50 specimens/assays vary System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: Daily maintenance < 5 minutes Primary Product: Sysmex® CA-7000 Coagulation Analyzer Methodologies Used: Optical based system, clotting, chromogenic and immunologic methodologies used Tests Available in the U.S.: PT, APTT, Fibrinogen, TT, Reptilase time, Factor Assays, drVVt screen and confirm, Factor V Leiden, Protein C clot, Protein S activity, AT III, Plasminogen, Factor VIII chromo, Alpha-2 Antiplasmin, Protein C chromo, Heparin, D-Dimer Throughput: 280 PT tests/hour, 480 PT/ APTT tests/hour Time to First Result: 7 minutes Sample Size: 50 µL PT, 100 µL APTT Frequency of Calibration: Assay dependent. CLIA guidelines

recommend calibration at least once every six months. More frequent calibration may be required if laboratory determines QC is outside of the acceptable range or as dictated by local regulations. Integrated Data Management: Yes Open Reagent System: Yes Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes Other Utility Requirements: Deionized water required, container or direct plumbed option What differentiates your product from other products on the market? Fastest throughput available for routine testing; standard in cap-piecing; PT, APTT results every 7 seconds; continuous loading of reagents, consumables and patient samples without interruption Operational Type: Continuous random access Sample Handling System: Rack Number of Reagent Containers Onboard/Tests/Container: 58 containers/tests vary Reagents Refrigerated Onboard: Yes Walkaway Capacity in Specimen/Tests Assays: 100 specimens/assays vary System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: Daily maintenance: <5 minutes

Primary Product: BCS® XP System

Methodologies Used: Optical based system. Clotting, chromogenic and immunologic

Tests Available in the U.S.: PT, APTT, Fibrinogen, TT, Reptilase time, Factor Assays, drVVt screen and confirm, Factor V Leiden, Protein C clot, Protein S activity, AT III, Plasminogen, Factor VIII chromo, Alpha-2 Antiplasmin, Protein C chromo, Heparin, Advanced D-Dimer, BC von Willebrand-risto. Cofactor assay

Throughput: 380 PT tests/hour; 325 PT/ APTT tests/hour

Time to First Result: <5 minutes