«laboratory analyzers buyers guide

»

Sample Size: 50 µL PT, 100 µL APTT

Frequency of Calibration: Assay dependent. CLIA guidelines recommend calibration at least once every six months.

Integrated Data Management: Yes

Open Reagent System: Yes

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes

Other Utility Requirement: Deionized water

once every six months. More frequent calibration may be required if laboratory determines QC is outside of the acceptable range or as dictated by local regulations.

Integrated Data Management: Yes

Open Reagent System: Yes

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes

Other Utility Requirements: Deionized water required

What differentiates your product from other products on the market? User-definable calibration curve expiration and pre-warning alerts; user-definable barcode utility enables customizable reagent protocols; user- friendly Windows XP software

Operational Type: Continuous random access

Sample Handling System: Rack

Number of Reagent Containers Onboard/Tests/Container: 90 containers/tests vary

What differentiates your product from other products on the market? Smallest footprint in its class; standard in cap-piecing; onboard quality control package; primary tube sampling and removable reagent trays

Operational Type: Continuous random access

Sample Handling System: Rack

Number of Reagent Containers Onboard/Tests/Container:

11 containers/tests vary Reagents Refrigerated Onboard:

Reagents Refrigerated Onboard: Yes

Walkaway Capacity in Specimen/Tests Assays: 100 specimens/assays vary

Yes Walkaway Capacity in Specimen/Tests Assays:

10 specimens/assays vary System Liquid or Dry:

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance: Daily maintenance: <5 minutes

Liquid Average Length of System Startup Time and Daily Maintenance:

Daily maintenance: <5 minutes

Primary Product: Sysmex® CA-560 Coagulation Analyzer

Methodologies Used: Optical based system. Clotting, chromogenic and immunologic

Tests Available in the U.S.: PT, APTT, Fibrinogen, TT, Factor Assays, Reptilase time, Protein C clot, AT III, Protein C chromo, Heparin, D-Dimer

Throughput: 54 PT tests/hour; 43 PT/APTT tests/hour

Time to First Result: 7 minutes

Sample Size: 50 µL PT, 100 µL APTT

Frequency of Calibration: Assay dependent. CLIA guidelines recommend calibration at least

Diagnostica Stago 5 Century Dr. Parsippany, NJ 07054 Contact: Anna Pambianchi Marketing Communications Specialist Telephone: (973) 631-1200 Fax: (973) 631-1618 anna.pambianchi@stago-us.com www.stago-us.com Primary Product: STA Compact Methodologies Used: Viscosity-based detection system for clotting assays; photo-optical methodology for chromogenic and immunologic assays Tests Available in the U.S.: PT, APTT, fibrinogen, D-dimer, thrombin time, Lupus A, intrinsic and extrinsic

factor assays, vWF, free Protein S, reptilase, Protein C & S, heparin (LMWH & UFH), AT, plasminogen, antiplasmin. Numerous assays are also available for research testing. Throughput: 150 PTs/hour Time to First Result: <5 minutes Sample Size: From 5 uL Frequency of Calibration: Varies with Assay Integrated Data Management: Yes Open Reagent System: Yes Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? Barcoded reagents throughout product line; mechanical detection system; standardized results throughout product line; reliable hardware; connectivity to total lab automation systems Operational Type: Continuous random access Sample Handling System: 96 samples Number of Reagent Containers Onboard/Tests/Container: 45 reagents/varies with assay Reagents Refrigerated Onboard: Yes Walkaway Capacity in Specimen/Tests Assays: Varies with model System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: No daily maintenance

Primary Product: STA-R Methodologies Used: Clotting, chromogenic, immunologic Tests Available in the U.S.: PT, APTT, fibrinogen, D-dimer, thrombin time, Lupus AC, intrinsic and extrinsic faxtor assays, vWF, free Protein S, reptilase, Protein C & S, heparin (LMWH & UFH), AT, plasminogen, antiplasmin. Numerous assays are also available for research testing Throughput: 300 PTs/hour

Time to First Result: <5 minutes

Sample Size: from 5 uL

Frequency of Calibration: Varies with assay

Integrated Data Management: Yes

Open Reagent System: Yes

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes

What differentiates your product from other products on the market? Total Lab Automation capable, mechanical clot detection using VDS (Viscosity-based Detection System), standardization among all equipment in the Stago product line, cap-piercing option

Operational Type: Continuous random access

Sample Handling System: 240 samples

Number of Reagent Containers Onboard/Tests/Container: 70 reagents/varies with assay

Reagents Refrigerated Onboard: Yes

Walkaway Capacity in Specimen/Tests Assays: 200 test set-ups

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance: <5 minutes, no daily maintenance

  • Drug TesTing

Dade Behring 1717 Deerfield Rd. Deerfield, IL 60015 Contact: Greg Apps Marketing Communications Specialist Telephone: (302) 631-9669 Fax: (302) 631-8511 www.dadebehring.com Primary Product: Viva-Jr.T Drug Testing System Type of Analyzer: Drug Testing Methodologies Used: EMIT® drugs of abuse assays, validity tests and serum tox assays Tests Available in the U.S.: Comprehensive DAT menu, adulteration