«laboratory analyzers buyers guide

»

tests and serum tox assays

Throughput: 66 EMIT® tests per hour

Time to First Result: 11-12 minutes

Sample Size: 2-30 µL per test, programmable in steps of 0.1µL

Frequency of Calibration: Once a week or when QC falls out of range

Integrated Data Management: Yes

Open Reagent System: Yes

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: No

Other Utility Requirements: Distilled or deionized water

What differentiates your product from other products on the market? The Viva-JrT features EMIT® assays for gold standard performance in a true benchtop system, plus winTOX® Integrated Data Management system

Operational Type: Semi-continuous random access

Separation Methodologies: Homogenous

Sample Handling System: Wheel

Number of Reagent Containers Onboard/Tests/Container: 9 tests onboard

Reagents Refrigerated Onboard: Yes

Walkaway Capacity in Specimen/Tests Assays: 25 samples

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance: <10 minutes

  • Hematology

Beckman Coulter Inc. 200 S. Kraemer Blvd. Brea, CA 92822

Contact: Mary Beth Johnson Marketing Manager Telephone: (714) 993-8438 Fax: (714) 961-3675 mbjohnson@beckman.com www.beckmancoulter.com

Primary Product: COULTER® Ac•TT 5diff / COULTER Ac•T

5diff CP / COULTER Ac•T 5diff AL Methodologies Used: Impedance, absorbance cytochemistry and volume (ACV) Tests Available in the U.S.: CBC, 5-part WBC differential Throughput: Up to 60 samples/hr or up to 80 samples/hr for AL Time to First Result: ~1 minute Sample Size: 30-53 mL Frequency of Calibration: Not specified Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? Low review rates; 5-part differential; closed vial sampling (Ac•TT 5diff CP); auto repeat, random access, match capabilities, autoloader (Ac•TT 5diff AL) Operational Type: Single sample; random access Sample Handling System: None or seven tube size tube holders for CP and AL, 10 tube racks, 10 rack autoloader for AL. Number of Reagent Containers Onboard/Tests/Container: Five/varies Reagents Refrigerated Onboard: No Walkaway Capacity in Specimen/Tests Assays: N/A for open vial or CP, 100 tube/load for AL System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: Start-up less than five minutes; no routine daily maintenance

Primary Product: COULTER® Ac•TT diff 2T Methodologies Used: Impedance, COULTER histogram differential Tests Available in the U.S.: CBC, 3-part differential Throughput: Up to 60 samples/hour

Time to First Result: Less than 60 seconds

Sample Size: 18 mL

Frequency of Calibration: Twice a year

Integrated Data Management: No

Open Reagent System: No

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes

What differentiates your product from other products on the market? Closed vial sampling; automatic validation of quality control data (high/low flagging); storage of up to 250 patient results

Operational Type: Batch

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance:

Less than five minutes, zero routine daily maintenance\

Primary Product: COULTER® LH 1511 Hematology Automation System

Integrated Data Management: Yes

Open Reagent System: No

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes

Other Utility Requirements: Air compressor

What differentiates your product from other products on the market? Completely automates the hematology process for pre-analytical to post-analytical processing

Operational Type: Continuous random access

Sample Handling System: Single tube

Methodologies Used: Coulter Principle, Bio-Physical Flow Cytometry, VCS, New Methylene Blue Reticulocyte Tests Available in the U.S.: CBC, 5-part differential, reticulocyte %, #, MRV, IRF Throughput: Up to 75 samples/hour Time to First Result: 1 minute 30 seconds Sample Size: 185 uL automatic, 125 uL manual, 50 uL pre-dilute Frequency of Calibration: Not specified by time; according to regulatory requirements Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? Combination of technologies and software Operational Type: Batch Separation Methodologies: Homogenous, no separation Sample Handling System: Cassettes Number of Reagent Containers Onboard/Tests/Container: Four containers-tests vary according to daily volume Reagents Refrigerated Onboard: No Walkaway Capacity in Specimen/Tests Assays: Yes, continuous feed System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: Operator has one keystroke for start up. Five minutes to start up. No daily maintenance.

Walkaway Capacity in Specimen/Tests Assays: Varies

Average Length of System Startup Time and Daily Maintenance: 15 minutes

Primary Product: COULTER® LH 500

Primary Product: COULTER® LH 750 and COULTER LH 780 Hematology Systems Methodologies Used: AccuCount technology combined with the Coulter impedance, flow cytometry; VCS differential technology.

Circle 79 on FREE Information Card