Consult the instructions supplied by the door manufacturer when attaching the garage door electric operator to the door.

Installation

Work on the electrical installation may only be carried out by an electri- cian registered with your local power supply utility.

The garage door electric operator may only be installed in dry premises.

Leave a gap of at least 5 – 15 mm bet- ween the highest point of the open door and the drive guiding rail.

The door must be activated by horizon- tally operating tractive or compressive forces. The required tractive/compres- sive force must not exceed 150 N (15 kp).

The connecting points on the ceiling, wall or lintel and door must ensure the safe connection of the garage door electric operator. Use additional structural meas- ures if required (couplings, supports, cross-beams, reinforcements).

Install a 230 V 50 Hz earthing-contact socket outlet within approximately 10 - 50 cm of the rear attachment point of the drive head. See technical data for fuse protection.

The mechanical components of the door should comply with the following stand- ards: EN 12 604 and EN 12 605.

Compliance with standards EN 12 453, EN 12 445 and prEN 12 635 is required when connecting the door drive to the door. The installation of additional pro- tective devices (light barrier, safety con- tact strip) must comply with standard prEN 12 978.

The manufacturer accepts no liability for technical defects in the drive door or for any structural defects occurring during use or following the improper mainte- nance of the door.

4

Scope of supply [2-3]

A

Drive unit

1

Drive head

2

Hand-held transmitter

3

Drive guiding rail

4

Rider

4.1

Rider – lower section

4.2

Closure

4.3

Rider – upper section

5

Toothed belt

6

Pulley

7

Switching cam (x2)

8

Antenna

9

Connecting section

10

Guiding rail

B

Suspension piece, complete

11

Perforated strip

12

Hexagonal head screw M8 x 25

13

Locking nut M8

14

Hexagonal head screw M6 x 90

15

Locking nut M6

16

Screw 8 x 70

17

Washer 8,4

18

Wall plug 10 mm

19

Suspension piece

C

Fixing parts, complete

20

Suspension elbows

21

Saucer head screw M8 x 16

22

Locking nut M8

23

Locking nut M10

24

Screw 8 x 70

25

Washer 8.4

26

Wall plug 10 mm

27

Mount

Installation examples

The garage door electric operator is suitable for the motorised operation of the following doors mounted as de- scribed:

Ceiling sectional door

  • -

    Lintel attachment

  • -

    Ceiling attachment

Side sectional door

  • -

    Mounting along the side wall

  • -

    Mounting above the door aperture

The garage door electric opera- tor is not suitable for the motorised op- eration of tilt-up doors.

Connection preparation

Incorrect connection may lead to serious injury. Follow the mounting in- structions provided.

Before starting installation, check and adjust the door for function as well as smooth movement. The tension of the springs must be adjust- ed so that the door can be easily opened and closed by hand. The door must run uniformly and smoothly.

Disconnect any mechanical locking de- vices on the door.

Unpack the garage door electrical opera- tor and accessories; check delivery. Keep the packaging in case the device has to be returned for repair.

Keep the packaging (e.g. plastic) out of the reach of children.

Only recyclable materials were used for the packaging of the garage door electric operator. Please dispose of the packaging material in accordance with local legislation.

Tools

[1]

Ensure that you have the neces- sary tools to hand.