Adjusting the lighting time The lighting time is the length of time during which the drive light is illuminat- ed after the motor has been running. Lighting time can easily be adjusted using switch 6 (from 2 seconds to max. 8.5 minutes). Lighting time is set to 2 minutes in the factory and switch 6 is set to the ”Off” position.

[55] Set lighting time via switch 6: Start up the motor and make the door travel to the final position (Open/Closed). Once the desired lighting time is reached, set switch 6 to the “On” position; the programmed time is memorised.

In order to modify a programmed lighting time, initially set switch 6 to the ”Off” position and then to position ”On” as described above. This is also re- quired after resetting.

Programming the soft run-out The soft run-out is a control function via which the door is returned to the closed position at reduced speed. The dura- tion of the soft run-out can be adjusted via switches 7 and 8. The soft run-out is set to 3 seconds in the factory with both switches in the ”Off” position.

Switch 7

Switch 8

Time

Off

Off

3s

Off

On

6s

On

Off

1.5 s

On

On

0s

[56] Programme the duration of the soft run-out via switches 7 and 8:

8

Additional safety connections

[57] On delivery, bridged Western plugs (4 = green, 3 = yellow) are inserted into the “Emergency Stop” (4) and “Safety strip/Light barrier” (3) exter- nal connections .

“Safety strip / Light barrier”

Connection (3) A safety device (safety strip or light barri- er) can be attached at this inlet:

[58] Unbolt, pull off and keep Western plug with yellow bridge. Install the safety device and con- nect by means of a Western plug.

Safety

Swit

ch

Switch

device

1

2

[59] Select the function of the safety de- vice via switches 1 and 2.

Test the function. If the installed safety device is activated as the door is closing, the door must stop and run back completely.

Off

Off

On

Off

On

On

(Off)

(On)

(Non-permissible setting)

Light barrier- contact inlet

Safety strip evaluation with 8.2 kOhm

Optical safety device

“Emergency-Stop” connection (4) An Emergency-Stop device (slip door safety device or Emergency-Stop Touch Contact) can be connected at this inlet:

[60] Unbolt, pull off and keep Western plug with green bridge. Install the Emergency-Stop device and connect by means of Western plug. Test the function. If the Not- Stop device is activated whilst the door is in operation, the motor must cut out immediately.

Additional lighting

Additional lighting may be con- nected only by a qualified electrician.

Additional lighting of 60 W max. (no lu- minescent tubes) can be connected in addition to the drive lighting (40 W).

[61] Connect additional lighting to clamps 1 and 2 (light) parallel to the drive light.

[61] Connection wiring

Terminals 1 - 6 and 10 - 18 on the motor electronics terminal board are connect- ed in the factory (= standard wiring).

Terminal

Standard connections

1

Light 230 V AC,

L connected, fuse-protected

2

Light 230 V AC, N

3

Trafo primary 230 V AC,

L fuse-protected

4

Trafo primary 230 V AC, N

5

Mains N 230 V AC

6

Mains L 230 V AC

7

(not connected)

10

Trafo secondary 24 V AC

11

Trafo secondary GND

12

Trafo secondary + 24 V AC

13

Motor (- on run-out)

14

Motor (+ on run-out)

15

OPEN limit switch

16

OPEN limit switch

17

CLOSED limit switch

18

CLOSED limit switch

Additional connections

8

Warning light 230 V AC,

L connected, fuse-protected

9

Warning light 230 V AC, N

19

0 Volt

20

Antenna

Mounting the lamp cover

[62-] Snap the lamp cover back on (1.2) [62-65].