Randolph County                                                                                                                     Bid 07-1001

Due Date:  Thursday, October 25, 2007, 3:00P.M.                                                         EMS Ambulances

_____________________________________________________________________________________

5.5.3No splices shall be permitted except for connection of "OEM pigtail-type" devices.  Butt splices are permitted for connection of OEM pigtail devices.  All connectors shall be UL approved.  Connection shall be machine applied to UL standards.  The use of insulation displacement type connectors, such as scotch lock type fasteners is NOT ACCEPTABLE.

Does your bid comply with this requirement?Yes   _____   No   _____

5.5.4The various wiring installations as supplied with this vehicle shall be of the automotive "harness: design. For ease of identification and future replacement these harnesses shall be engineered and manufactured in the following sections:

1.Engine compartment harness.

2.Driver's control console harness.

3.Electrical component panel harness.

4.Main module harness.

5.Chassis rear lighting harness.

6.Printed circuit board

These five (5) harnesses is the minimum requirement, please explain on the "exceptions" page (12.1) if the vehicle you are bidding contains less. This Agency is extremely concerned with the availability of future replacement harnesses.

THE MANUFACTURER OF THE AMBULANCE BID SHALL NOT SUBCONTRACT THE CONSTRUCTION OF THESE HARNESSES. SPECIAL NOTICE TO BIDDERS. This requirement is made to insure this Agency of the manufacturer's ability to control warranty and replace the aforementioned harnesses in a timely manner.

Does your bid comply with this requirement?Yes   _____   No   _____

5.6

    Wiring Criteria:   

All wiring devices, switches, outlets, etc., except circuit breakers, shall be rated to carry at least 125% of the maximum ampere load for which the circuit is protected. There shall be a master electrical component panel located in the ambulance. It is preferred that this panel be mounted on or near the bulkhead of the patient compartment.  Standard circuit breakers, relays, and diodes shall be mounted on a printed circuit panel and shall be easily accessible through a door or hatch.  All components on the circuit board are to be permanently labeled as to their function.

Does your bid comply with this requirement?Yes   _____   No   _____

Page 20 of 56