Randolph County                                                                                                                     Bid 07-1001

Due Date:  Thursday, October 25, 2007, 3:00P.M.                                                         EMS Ambulances



Grab Handles:

Handicapped style grab handles shall be provided on each patient door.  Each handle shall be constructed of 1" stainless steel and shall be in an "L" shape to give both low and high level support.  The handles shall be securely bolted into tapping plates installed within the door frame.

Does your bid comply with this requirement?Yes   _____   No   _____


The floor shall be at the lowest level permitted by clearances, but not more than 33 inches from the ground.  The floor structure shall consist of a minimum of 2" x 2" x .125" structural box section 6061-T6 aluminum.  The finished floor assembly shall be securely welded to the wall structures and exterior compartments.  All critical load points shall be reinforced with 1/4 inch x 3 x 4 gusset plates.  Above the floor channels, there shall be an aluminum moisture shield .050 inches thick.

Does your bid comply with this requirement?Yes   _____   No   _____

8.9.1A top floor shall be of seven ply ¾" boat grade plywood, sanded both sides with no voids, and shall be installed over the moisture barrier. The plywood shall be marine resin coated prior to installation to prevent warping due to ambient moisture absorption. The plywood floor shall be one piece from the bulkhead to the rear doors between the patient door steeple and squad bench and extend under the street side cabinets. The plywood floor shall be securely anchored to the floor sub structure with ¼" UNF machine by two and one half inch screws.  

The flooring shall extend the full length and width of the patient compartment including the space under the cabinets.  Flooring shall be slip and blood borne pathogen resistant.

Does your bid comply with this requirement?Yes   _____   No   _____

8.9.2The entire underside of the modular body shall be sealed.  All hollow structural shapes or cavities shall be sealed utilizing approved expandable foam insulation.

Does your bid comply with this requirement?Yes   _____   No   _____

8.9.3The rear patient access shall be equipped with an exterior aluminum threshold mount to the lower door jam.  This threshold will protect bottom door jam when loading one-man cot.  In addition, the rear patient floor shall have a 14 gauge stainless steel cot protector

Does your bid comply with this requirement?Yes   _____   No   _____