Patient Restraints:

Patient restraints shall be as specified in paragraph 3.11.8 of Federal Specification


Does your bid comply with this requirement?Yes   _____   No   _____

8.25 IV Holders for Intravenous Fluid Containers:  

IV holders for intravenous fluid containers shall be as specified in paragraph 3.11.9 of Federal Specification KKK-A- 1822E.

Does your bid comply with this requirement?Yes   _____   No   _____

8.26 Oxygen, Main Supply and Installation:  

The ambulance shall have a hospital type piped oxygen system capable of storing and supplying a minimum of 3,000 liters of medical oxygen.  The cylinder controls shall be accessible from inside the patient compartment.  The pressure gauge shall be visible from either the attendant's seat or from the squad bench.  The oxygen shall be piped to two (2) self-sealing Ohio adaptable oxygen outlets located in the action area and one (1) oxygen outlet at the head of the secondary patient. The oxygen system will incorporate electrically conducted oxygen hose with a working pressure of 150 PSI.  

All oxygen hose/outlet connections will use machine crimped brass ferrules and high pressure connectors.  The entire oxygen delivery system will be pressure tested with a minimum of 150 PSI of nitrogen gas for a period of 4 hours.  The testing documentation shall be delivered with each vehicle.

Does your bid comply with this requirement?Yes   _____   No   _____

8.27Suction Aspirator, Primary Patient:  

The ambulance shall be supplied with an on board vacuum aspirator. The unit shall be of impact resistance autoclavable.  The discharge side of the vacuum pump shall be vented to the outside of the vehicle via sealed tubing, formed collection jar with a dual sealing lid assembly.  The removable lid shall incorporate a variable position adjustment valve and gauge system.  The vacuum shall be via an installed 12 volt DC suction pump.  The on/off switch is to be located in the attendant's console.

Does your bid comply with this requirement?Yes   _____   No   _____

8.28     Infectious Waste Receptacles:

           The ambulance shall not contain any built-in infectious waste receptacles for sharps or

           bio-hazard trash.

Does your bid comply with this requirement?Yes   _____   No   _____

Page 43 of 56