Randolph County                                                                                                                     Bid 07-1001

Due Date:  Thursday, October 25, 2007, 3:00P.M.                                                         EMS Ambulances

_____________________________________________________________________________________

9.0 ENVIRONMENTAL SYSTEMS

9.1

Driver’s Compartment Environmental Equipment:  

The driver’s compartment shall be furnished with OEM hot water, fresh air, high capacity, heavy-duty heater with dual defrosters and dehumidifying air conditioning system.  Systems shall provide outside air and variable mixtures as desired, circulating conditioned air through the compartment in compliance with environmental criteria specified herein.

Does your bid comply with this requirement?Yes   _____   No   _____

9.2Patient Compartment Environmental Equipment:  

This Agency is committed to keep our staff and patients safe by utilizing technology available in today's market place.  Therefore, it shall be incumbent for all primary manufacturers to provide the maximum protection from airborne pathogens and eliminate obnoxious odors that can create discomfort for staff and patients. The patient compartment shall be heated and air conditioned by a filtered system that complies with the performance standards set forth in KKK-A-1822E. The air conditioning/heating unit shall be accessible for service through a "tilt-out" access panel in the dedicated environmental cabinet on the bulkhead.  A thermostat and fan speed control shall be installed in the action area panel.

Does your bid comply with this requirement?Yes   _____   No   _____

9.2

Heating Criteria:  

Heating shall meet the performance requirements of paragraph 3.13.4 of Federal Specification KKK-A-1822E.

Does your bid comply with this requirement?Yes   _____   No   _____

9.3

Air Conditioning Criteria:  

Air-conditioning shall meet the performance requirements of paragraph 3.13.5 of Federal Specification KKK-A-1822E.

Does your bid comply with this requirement?Yes   _____   No   _____

9.4Ventilation Criteria:

Ventilation system(s) of the driver and patient compartments shall provide complete change of ambient air within each compartment at least every two minutes with the vehicle stationary.  Ventilation shall be separately controlled within each compartment.  Fresh air intakes shall be located towards the front of the vehicle and exhaust vents shall be located on the upper rear of the vehicle.  The patient compartment shall be ventilated by the air delivery system of the environmental equipment (heater – air conditioner) or by separate system(s) such as power intake, exhaust ventilator(s).  External condenser shall be included to assist with cooling and shall be mounted at curbside step well.

Does your bid comply with this requirement?Yes   _____   No   _____