Randolph County                                                                                                                     Bid 07-1001

Due Date:  Thursday, October 25, 2007, 3:00P.M.                                                         EMS Ambulances

_____________________________________________________________________________________

13.0TESTS

13.1Test Criteria:  

The Bidder is obligated to prove that the vehicle, ambulance components and equipment offered/provided meet or exceed the requirements of this specification and of compliance to Federal Ambulance Specification KKK-A-1822E and any of its amendments in effect at the time of this bid.

Does your bid comply with this requirement?Yes   _____   No   _____

13.1.1Copies shall be provided with this bid of the test documents and a letter from the independent testing laboratory that performed the tests certifying that the following tests have been conducted and passed.  Test documents or any source other than described above shall not be accepted.  Failure to comply with these requirements shall be considered as non-responsive and will not be accepted.  The certified tests are as follows and conform to the requirements of this specification and Federal Ambulance Specification KKK-A-1822E.  

Does your bid comply with this requirement?Yes   _____   No   _____

13.1.2The following performance tests on the ambulance items, systems, and equipment shall be submitted on the ambulance model bid.  The complete test document from an independent testing laboratory shall be submitted with the bid proposal.  The paragraph numbers referenced below are those of Federal Ambulance Specification KKK-A-1822E.

A.Vehicle Physical Dimensions (3.4.11 through 3.4.11.6).

B.Patient Compartment Interior Dimensions (3.10.4).

C.Step well, Bumpers and Steps (3.10.12 and 3.9.6).

D.Storage Compartment and Facilitation (3.11 through 3.11.2.1, 3.11.4 & 3.11.6).

E.Ambulance Body and Patient Area (3.10.1 through 3.10.3, 3.10.6 through 3.10.8, 3.10.10 through 3.10.11, 3.10.3 through 3.10.16 and 3.9.9).

F.

Vehicle Weight Distribution (4.4.3 and 3.5 through 3.5.6 and

3.19)                                                   

G.Water Spray Test (4.4.5).

H.115 VAC Utility Power (3.7.8 through 3.7.8.3).

I.Electrical System Components (3.7.8. through 3.7.8.3, 3.7 through 3.7.5, 3.7.7 through 3.7.7.4, 3.7.9 through 3.7.11, 3.8.1, 3.8.4 and 3.8.50).

J.Patient Compartment Illumination (3.8.5.1).

K.Electrical Generating System (3.7.6 through 3.7.6.3 and AMD 05).

L.Warning Lights and Siren System (3.8.2 through 3.8.4 and 3.14.6).

M.Door Latches, Hinges and Hardware (3.10.9).

N.Static Load Test (3.10.5 and AMD 001).

O.Patient Compartment Interior Surfaces (3.10.17 and FMVSS 302).

P.Oxygen System Test (4.4.6, 3.12.1 and 3.12.1.1).

Page 50 of 56