Typical startup procedures

Verify that equipment visually appears safe IE: Hose condition, visibility of gauges

Clean torch orifices with a “tip cleaners” (a small wire gauge file set used to clean slag and dirt form the torch tip)

Crack (or open) cylinder valves slightly allowing pressure to enter the regulators slowly

Opening the cylinder valve quickly will “Slam” the regulator and will cause failure.