X hits on this document

PDF document

Master of Science Thesis in Electric Power Engineering - page 32 / 114

365 views

0 shares

3 downloads

0 comments

32 / 114

VOLTAGE ORIENTED CONTROL – SIMULATION

  • good accuracy current tracking,

  • less sensitive to parameter variations.

(Sources :[4] [9] ).

3.4.3 Design of the synchronous PI controller

Figure 3.7 : Synchronous coordinates schematic (see APPENDIX AA.5)

 Synchronous coordinates equation (notation,

)

(3.4)

And the system transfer function

is

1

(3.5)

Figure 3.8 : Current control with inner decoupling loop

 Cross coupling cancellation

The first step in the controller design is to cancel the cross coupling initiated by the term

(since multiplication by

maps the

axis on

axis and vice versa). This easily possible if we

have an accurate estimation of According to [9] , a PI current

which is controller

. has

no

satisfactory

tracing

performance

for

the

coupled

system described by equations (2.17)(2.18). For high performance and accuracy current tracking we

need to cancel this cross coupling. We select

as

(3.6)

with

the estimated value of . Then, if

and

we get

23

Document info
Document views365
Page views373
Page last viewedSat Dec 10 12:01:52 UTC 2016
Pages114
Paragraphs2263
Words17018

Comments