FLOORING

701

CARPET

Install Action Bac carpet with a separate half-inch thickness bonded-urethane pad. Carpet will be 100% nylon fiber, min. 25 oz. face weight, and have a Class A fire rating. All seams will be secured with carpet seaming tape. Carpet will be secured with metal strips where carpet meets flooring of other rooms. Installing tack strips and stretching shall be in accordance with industry standards. Carpet to be

chosen by owner from selected samples. Quality and price to be mid-range.

702 VINYL Install plywood underlayment minimum thickness 3/16".

A maximum spacing of 1/16" is allowed for

butt joints and side joints of all panels. Use appropriate joint compound for support. Sand joints smooth.

Nail with coated or ring shank nails spaced 4" apart, glue or staple as necessary.

Install vinyl floor tile or sheet goods of minimum thickness of .065 gauge and 10-mil wear layer. The outer edge of the room will be trimmed with a finished quarter round or base shoe. Bath flooring will be trimmed to within ⅛" of the tub line and caulked with a silicone caulk. Adhesive shall be a type designed for this purpose and applied in accordance with the manufacturers specifications. Finished work shall be free from protrusion of any kind. Vinyl to be chosen by owner from selected samples. Quality and price to be mid-range.

703

LAMINATE FLOORING

Install laminate flooring to manufactures specifications. Use “best quality” underlayment mat. The outer edge of the room will be trimmed with a finished quarter round or base shoe to match. Flooring to be

chosen by owner from selected samples. Quality and price to be mid-range.

704

SUB-FLOOR REPAIR

If subfloor repair is necessary, remove any plywood that is deteriorated and replace with appropriate size and thickness of plywood or OSB meeting building codes. Also check joist for any deterioration and

make applicable repairs.

800

INSULATION

801

R-11 ROLLED

Install fiberglass or similar spun insulating material. Insulation must be 3½" or more thick, either 15" or 23" in width; R-11 and backed with saturated paper or aluminum foil. Tack with stapler if paper backed. Rolled and batt type shall fit snugly between studs and rafters. Runs should be as long as possible with

joints well fitted. Friction fit insulation may be used where no stapling is needed.

802

R-19 ROLLED

Install fiberglass or similar spun insulating material. Insulation must be 5½" or more thick, either 15" or 23" in width; R-19 and backed with saturated paper or aluminum foil. Tack with stapler if paper backed. Rolled and batt type shall fit snugly between studs and rafters. Runs should be as long as possible with

joints well fitted. Friction fit insulation may be used where no stapling is needed.

803

VAPOR BARRIER

Vapor barrier of 4-mil plastic will be used on all exposed wall surfaces.

\\citycr.local\sharedocs\PublicWorks\HSG\Housing Rehab\Specs-Codes\General Specifications.doc