X hits on this document

188 views

0 shares

0 downloads

0 comments

19 / 74

CONFIGURATION INFORMATION

Page 19 of 74

Host System(s) and Tested Storag

e Configuration Components

Host System: 2 – IBM System x3850 X5 Server each with:

Tested Storage Configuration (TSC): Huawei Symantec UltraPath For Windows/Linux

4 – Intel Xeon E7530 1.86 GHz 6 Core Processors with 12 MB L2 cache per processor

8 – Qlogic dual-port QLE2562 FC HBAs

64 GB main memory

Huawei Symantec Oceanspace S8100 (8-node)

Windows Server 2003 Enterprise Edition 64-bit with SP2

8 – Active-Active service controllers in 4 service controller groups

PCIe

2 service controllers per service controller group 8 GB cache per service controller (64 GB total) 16 – Fibre Channel 4-port adapters (4 Gbps)

4 – 4 Gbps front-end connections per service controller (32 total, 16 used))

32 – 4 Gbps SFPs

16 – Active-Active data controllers in 8 service controller groups

2 data controllers per data controller group 16 GB cache per data controller (256 GB total)

4 – 4 Gbps backend connections per data controller (64 total, 64 used)

160 – 4 Gbps SFPs

18 – 15K RPM FC disk drives included in each data controller group (144 disk drives total)

2 – Data Switch Modules

2 – Management Switch Modules

8 – Ethernet 4-Port Adapters (1 Gbps)

56– S8100 Disk Expansion each with four 4 Gbps SFPs (224 SFPs total) and 18 15K RPM FC disk drives (1,008 disk drives total)

1,152 –15K RPM FC disk drives 628 – 600 GB 15K RPM disk drives 330 – 450 GB 15K RPM disk drives 194 – 300 GB 15K RPM disk drives

Customer Tunable Parameters and Options Clause 9.4.3.5.1

All Benchmark Configuration (BC) components with customer tunable parameter and options that have been altered from their default values must be listed in the FDR. The FDR entry for each of those components must include both the name of the component and the altered value of the parameter or option. If the parameter name is not self-explanatory to a knowledgeable practitioner, a brief description of the parameter’s use must also be included in the FDR entry.

“Appendix B: Customer Tunable Parameters and Options” on page 63 contains the customer tunable parameters and options that have been altered from their default values

for this benchmark.

SPC BENCHMARK 1™ V1.12

FULL DISCLOSURE REPORT

Huawei Symantec Technologies Co., Ltd. Huawei Symantec Oceanspace™ S8100 (8-node)

Submission Identifier: A00099 Submitted for Review: NOVEMBER 11, 2010

Document info
Document views188
Page views188
Page last viewedMon Dec 05 09:33:33 UTC 2016
Pages74
Paragraphs6246
Words21133

Comments