SPC-1 BENCHMARK EXECUTION RESULTS REPEATABILITY TEST

Page 44 of 74

Repeatability Test Clause 5.4.5

The Repeatability Test demonstrates the repeatability and reproducibility of the SPC-1 IOPS™ primary metric and SPC-1 LRT™ metric generated in earlier Test Runs.

There are two identical Repeatability Test Phases. Each Test Phase contains two Test Runs. Each of the Test Runs will have a Measurement Interval of no less than ten (10) minutes. The two Test Runs in each Test Phase will be executed without interruption or any type of manual intervention.

The first Test Run in each Test Phase is executed at the 10% load point. The Average Response Time from each of the Test Runs is compared to the SPC-1 LRT™ metric. Each Average Response Time value must be less than the SPC-1 LRT™ metric plus 5% or less than the SPC-1 LRT™ metric plus one (1) millisecond (ms).

The second Test Run in each Test Phase is executed at the 100% load point. The I/O Request Throughput from the Test Runs is compared to the SPC-1 IOPS™ primary metric. Each I/O Request Throughput value must be greater than the SPC-1 IOPS™ primary metric minus 5%. In addition, the Average Response Time for each Test Run cannot exceed 30 milliseconds.

If any of the above constraints are not met, the benchmark measurement is invalid.

Clause 9.4.3.7.4 The following content shall appear in the FDR for each Test Run in the two Repeatability Test Phases:

  • 1.

    A table containing the results of the Repeatability Test.

  • 2.

    An I/O Request Throughput Distribution graph and table.

  • 3.

    An Average Response Time Distribution graph and table.

  • 4.

    The human readable Test Run Results File produced by the Workload Generator.

  • 5.

    A listing or screen image of all input parameters supplied to the Workload Generator.

SPC-1 Workload Generator Input Parameters

The SPC-1 Workload Generator input parameters for the Sustainability, IOPS, Response Time Ramp, Repeatability, and Persistence Test Runs are documented in “Appendix E: SPC-1 Workload Generator Input Parameters” on Page 73.

SPC BENCHMARK 1™ V1.12

FULL DISCLOSURE REPORT

Huawei Symantec Technologies Co., Ltd. Huawei Symantec Oceanspace™ S8100 (8-node)

Submission Identifier: A00099 Submitted for Review: NOVEMBER 11, 2010

Document info
Document views228
Page views228
Page last viewedSun Dec 11 10:39:44 UTC 2016
Pages74
Paragraphs6246
Words21133

Comments