SPC-1 BENCHMARK EXECUTION RESULTS DATA PERSISTENCE TEST

Page 57 of 74

Data Persistence Test Results

Data Persistence Test Results Data Persistence Test Run Number: 1

Total Number of Logical Blocks Written Total Number of Logical Blocks Verified Total Number of Logical Blocks that Failed Verification Time Duration for Writing Test Logical Blocks Size in Bytes of each Logical Block Number of Failed I/O Requests in the process of the Test

0 5 minutes 1024 0

If approved by the SPC Auditor, the SPC-2 Persistence Test may be used to meet the SPC-1 persistence requirements. Both the SPC-1 and SPC-2 Persistence Tests provide the same level of functionality and verification of data integrity. The SPC-2 Persistence Test may be easily configured to address an SPC-1 storage configuration. The SPC-2 Persistence Test extends the size of storage configurations that may be tested and significantly reduces the test duration of such configurations.

The SPC-2 Persistence Test was approved for use in this set of audited measurements.

In some cases the same address was the target of multiple writes, which resulted in more Logical Blocks Written than Logical Blocks Verified. In the case of multiple writes to the same address, the pattern written and verified must be associated with the last write to that address.

SPC BENCHMARK 1™ V1.12

FULL DISCLOSURE REPORT

Huawei Symantec Technologies Co., Ltd. Huawei Symantec Oceanspace™ S8100 (8-node)

Submission Identifier: A00099 Submitted for Review: NOVEMBER 11, 2010