X hits on this document

498 views

0 shares

0 downloads

0 comments

53 / 182

DISASSEMBLY AND REASSEMBLY SHIFTING CONTROLS

A. Removal and Disassembly

1.

Turn out the four retaining capscrews, jar lightly to break gasket seal and remove the gear shift lever housing and gasket from shift bar housing. NOTE: Remote control housings are removed from shift bar housing in the same manner. For disassembly and reassembly of LRC Assemblies, see Illustrated Parts List No. P-541. For disas- sembly and reassembly of SRC Assemblies, see Illustrated Parts List No. P-515.

2. Remove the boot from gear shift lever and secure assembly in vise with bottom of housing up. Use a large screwdriver to twist between the spring and housing, forcing the spring from under the lugs in housing. Do one coil at a time.

Document info
Document views498
Page views498
Page last viewedSat Dec 10 00:07:31 UTC 2016
Pages182
Paragraphs2411
Words25289

Comments