Quick Set-Up

The error message, in this case, means that the DIU 2130 is new and has never been assigned to any CSU module in any slot of any shelf. Ignore this error message.

Then the DIU 2130 Configuration Menu is displayed.

Figure 2-4

DIU 2130 Configuration Menu

C) CSU

[ 0,0 ]

T) timing source

CSU

  • ---

    DIU

    • S)

      save config

2130

CONFIGURATION/DIAGNOSTIC

MENU

---

Q) restore config

X) exit menu

chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Dp)port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Lead Toggles

DTR)

DSR)

RTS)

CTS)

DCD)

Forced Ports

-/-

-/-

-/-

-/-

-/-

Port 1

Mp)

mode

56K

Sp)

scram/hdlc inv

N/N

Kp)

clocking

ST

Gp)

LOS lead

NONE

Ep)

enable loop

Np)

near loopback

Fp)

far loopback

YES OFF OFF

Port 2 56K N/N ST NONE

Statistics FW/HW Rev...1.6/0.8 Battery.....OK DTE Intf....V.35/V.35 Data bus....NONE

YES OFF OFF

Tp) Pp) A)

test and monitor BEC monitor leads and status enable alarm reporting...YES

[1,2] DIU 2130 >

NOTE: For the remainder of this chapter you will not be instructed to press ENTER each time. Generally, the ENTER key is used after each command or value entry.

The CSU command is used to assign the DIU 2130 module to the CSU with which it will be used. Since the NCC 2020 contains a TAC 2010 CSU module, it will be used for the CSU in this example. Type “C”. At the prompt enter shelf > type “1”, at the prompt enter slot > type “1” again. This selects the NCC 2020 in slot one of shelf one as the CSU for this DIU 2130 module.

The Timing Source defaults to CSU, meaning that the DIU 2130 will derive its transmit clock from the source selected in the CSU configuration (recovered network clock in this example). This is correct for this example.

In the middle of the display, a line across the screen lists all 24 timeslots. The DS0 (timeslot) selection prompt appears at the beginning of the next line, Dp. The lowercase p is a variable,

Verilink NCC 2020 User Manual

2-5