940Manufactured/Certified Mobile Home Installation Requirements

1.Installation Standards

a.Permanent Perimeter Enclosure

                 Those manufactured homes designated in the Zoning Ordinance

                 as requiring a permanent perimeter enclosure must be set onto an

                 excavated area, with foundations, footings and crawl space or

                 basement walls constructed in accordance with the terms of the

                 One and Two Family Dwelling Code.  The space between the floor

                  joists of the home and the excavated under floor grade shall be

                 completely enclosed with the permanent perimeter enclosure (except

                 for required openings).

b.Foundation Siding/Skirting (for temporary structures)

                  All manufactured or certified mobile homes without a permanent

                  perimeter enclosure shall have an approved foundation siding/skirting

                  enclosing the entire perimeter of the home.  Foundation siding/skirting

                  and back-up framing shall be weather-resistant, non-combustible

                  or self-extinguishing materials, which blend with the exterior siding

                  of the home.  Below grade level and for a minimum distance of six

                  (6) inches above finish grade, the materials shall be unaffected by

                  decay or oxidation. The siding shall be installed in

                  accordance with manufacturer's recommendations or approved equal


                  The siding shall be ventilated by openings, which shall have a net area of                      not less than one and one-half (1-1/2) square feet for each twenty-five (25) linear feet of exterior perimeter.  The openings shall be covered with                            corrosion resistant wire mesh not larger than one half (1/2) inch in any                          dimension.  The under floor area shall be provided with an eighteen (18)                       inch by twenty-four (24) inch minimum size access crawl hole, which                            shall not be blocked by pipes, ducts, or other construction interfering with                    the accessibility of the under floor space, or other approved access                              mechanism.