X hits on this document

PDF document

Sample Specifications for Rosco Subfloor System – - page 3 / 8

21 views

0 shares

0 downloads

0 comments

3 / 8

  • B.

    Subfloor: Rosco Laboratories Inc. Subfloor System temporarily installed consisting of the following:

    • 1.

      Rosco Subfloor System Panels consisting of:

      • a.

        1” thick closed cell foam pads

      • b.

        ½” Medium Density Fiberboard Sleeper Layer

      • c.

        ½” Medium Density Fiberboard Top Surface Layer

      • d.

        Panels are glued in the factory with wood composite glue and minimum adequate clamping force (1872 psf minimum uniformly applied for at least 30 minutes).

      • e.

        Panels are edge rounted with 1/16” roundovers on all exposed edges.

      • f.

        Panels are joined with extended wavelock tabs and corresponding recesses in the sleeper layer.

      • g.

        All Medium Density Fiberboard to be homogenous domestically sourced hardwood based and domestically manufactured.

      • h.

        All materials to be warehoused within prescribed humidity requirements of the manufacturer.

      • i.

        All panel batches are to be checked against caliper standards for length and width and edge swelling standards.

    • 2.

      The edge of the subfloor is finished with Rosco Subfloor System Perimeter consisting of:

      • a.

        2 layers ½” Medium Density Fiberboard Support Layers

      • b.

        ½” Medium Density Fiberboard Sleeper Layer with inset threaded insert

      • c.

        ½” removable Medium Density Fiberboard Perimeter Caps.

      • d.

        ¼” – 20 x 1 ¼” zinc plated steel flat head machine screws to join to the Top Surface layer to the Sleeper layer

      • e.

        Sleeper and Support layers are glued in the factory with wood composite glue and adequate clamping force (1872 psf minimum uniformly applied for at least 30 minutes).

      • f.

        Perimeter Caps and Sleepers are edge rounted with 1/16” roundovers on all exposed edges.

      • g.

        Perimeter are joined to panels with extended wavelock tabs and corresponding recesses in the sleeper layer.

      • h.

        All Medium Density Fiberboard to be homogenous domestically sourced hardwood based and domestically manufactured.

      • i.

        All materials to be warehoused within prescribed humidity requirements of the manufacturer.

    • 3.

      As needed, ADA Compliant Rosco Subfloor System ramps are to be installed and attached to the sleeper layer of the perimeter.

    • 4.

      Subfloor to be kept back from all walls by ½

    • 5.

      Subfloor Performance must comply with ESTA E1-26 (2006) performance standards.

Specialty Dance / Performance Floor Assemblies

Section 09646

Document info
Document views21
Page views21
Page last viewedSat Dec 10 03:26:18 UTC 2016
Pages8
Paragraphs292
Words2161

Comments